  "revisions": [
    {
      "id": "r04-mep-piscina-2026-10-17",
      "model_commit": "5440edbd02e992135a4d56ea2d29a6b547529dc0",
      "url": "https://casadfl.xyzbim.eu/revisoes/r04-mep-piscina-2026-10-17/mep/"
    },
    {
      "id": "r05-lower-plus-1m-2026-10-17",
      "parent": "r04-mep-piscina-2026-10-17",
      "architecture_reference": "r03-investigacao-2026-10-12",
      "model_commit": "f905d4fe293cd1c0be01489a9009d82f6755040c",
      "delivery_commit": "c4e3ddce6277efb1cfed419f959e0f8a4d8f367d",
      "packaging_commit": "6d60c744a59dca04c0f160f7d3c33f4947a35cda",
      "branch": "codex/dfl-lower-plus-1m",
      "git_tag": "dfl/r05-lower-plus-1m-2026-10-17",
      "url": "https://casadfl.xyzbim.eu/revisoes/r05-lower-plus-1m-2026-10-17/mep/",
      "changes": [
        "Lower living floor, pool and lower landscape +1 m; roofs fixed",
        "Coordinated services, stairs and facade proposal",
        "Survey-based cut/fill comparison with material-reuse sensitivities"
      ],
      "status": "sealed_local_deployment_pending"
    },
    {
      "id": "r06-sewer-shallow-return-2026-10-17",
      "parent": "r05-lower-plus-1m-2026-10-17",
      "architecture_reference": "r03-investigacao-2026-10-12",
      "model_commit": "a36a25b93233b2a40b55fe83937512bc216b6bbd",
      "delivery_commit": "a36a25b93233b2a40b55fe83937512bc216b6bbd",
      "packaging_commit": "0c5f6b8dad573afe8eaa9a7ac8ab07251dbe90cd",
      "branch": "codex/dfl-public-sewer",
      "git_tag": "dfl/r06-sewer-shallow-return-2026-10-17",
      "url": "https://casadfl.xyzbim.eu/revisoes/r06-sewer-shallow-return-2026-10-17/mep/",
      "changes": [
        "Public connection at surveyed SAN chamber; invert assumed 2 m below road",
        "Raised barbecue pumped return in protected terrace service run",
        "r05 architecture, pool, terrain and earthworks preserved"
      ],
      "status": "sealed_local_deployment_pending"
    },
    {
      "id": "r07-integrated-services-2026-10-17",
      "parent": "r06-sewer-shallow-return-2026-10-17",
      "architecture_reference": "r03-investigacao-2026-10-12",
      "model_commit": "b069d02fb41e6de71343246761210a05fec6952e",
      "delivery_commit": "b069d02fb41e6de71343246761210a05fec6952e",
      "packaging_commit": "b069d02fb41e6de71343246761210a05fec6952e",
      "branch": "codex/dfl-services-economy",
      "git_tag": "dfl/r07-integrated-services-2026-10-17",
      "url": "https://casadfl.xyzbim.eu/revisoes/r07-integrated-services-2026-10-17/mep/",
      "changes": [
        "Existing terrace gutters reused; shallow water and electrical routes",
        "Sewage station at lower entrance and pool plant beneath deck",
        "Roof heat pump and photovoltaic array; bedroom radiant floor loops",
        "Concealed barbecue greywater ventilation; storm bypass along pool edge",
        "Validated r05 architecture, pool, terrain and earthworks preserved"
      ],
      "status": "sealed_local_deployment_pending"
    }
  ],
  "commits": [
    {
      "id": "4222fb1d2c9fc2280bc3619b4a253008266bf268",
      "parents": [
        "5440edbd02e992135a4d56ea2d29a6b547529dc0"
      ],
      "title": "Archive DFL MEP baseline for append-only publication"
    },
    {
      "id": "97a39ad2a1c1e8ccddd7e16b4f2201c076b969ef",
      "parents": [
        "4222fb1d2c9fc2280bc3619b4a253008266bf268"
      ],
      "title": "Record verified DFL r04 publication"
    },
    {
      "id": "f905d4fe293cd1c0be01489a9009d82f6755040c",
      "parents": [
        "97a39ad2a1c1e8ccddd7e16b4f2201c076b969ef"
      ],
      "title": "Study DFL lower floor pool and terrain raised 1m under fixed roof"
    },
    {
      "id": "c4e3ddce6277efb1cfed419f959e0f8a4d8f367d",
      "parents": [
        "f905d4fe293cd1c0be01489a9009d82f6755040c"
      ],
      "title": "Clarify alternative IFC assembly and record verification"
    },
    {
      "id": "6d60c744a59dca04c0f160f7d3c33f4947a35cda",
      "parents": [
        "c4e3ddce6277efb1cfed419f959e0f8a4d8f367d"
      ],
      "title": "Publish DFL alternatives with immutable revisions and Git ancestry"
    },
    {
      "id": "4a740f71665dd4a833e0f490a7b459a723d1b869",
      "parents": [
        "6d60c744a59dca04c0f160f7d3c33f4947a35cda"
      ],
      "title": "Record sealed DFL r05 raised alternative and parent revision"
    },
    {
      "id": "827885bfae38937fc5bf1c08cd2b0191d36ed389",
      "parents": [
        "4a740f71665dd4a833e0f490a7b459a723d1b869"
      ],
      "title": "Record verified r05 deployment"
    },
    {
      "id": "f428701a99d17ac159ecea4ee6d05fad84ed7509",
      "parents": [
        "827885bfae38937fc5bf1c08cd2b0191d36ed389"
      ],
      "title": "Connect DFL wastewater proposal to surveyed SAN chamber at assumed invert"
    },
    {
      "id": "a36a25b93233b2a40b55fe83937512bc216b6bbd",
      "parents": [
        "f428701a99d17ac159ecea4ee6d05fad84ed7509"
      ],
      "title": "Raise DFL barbecue pressure return into protected terrace service run"
    },
    {
      "id": "0c5f6b8dad573afe8eaa9a7ac8ab07251dbe90cd",
      "parents": [
        "a36a25b93233b2a40b55fe83937512bc216b6bbd"
      ],
      "title": "Package DFL service revisions with preserved geometry and Git ancestry"
    },
    {
      "id": "de978c056aad9c54f95923f57eafc9d31d8d9a0c",
      "parents": [
        "0c5f6b8dad573afe8eaa9a7ac8ab07251dbe90cd"
      ],
      "title": "Record sealed DFL r06 sewer and shallow return revision"
    },
    {
      "id": "54374f4f80b704cd93d11658f1ecc1aa7739df10",
      "parents": [
        "de978c056aad9c54f95923f57eafc9d31d8d9a0c"
      ],
      "title": "Record verified Casa DFL r06 public deployment"
    },
    {
      "id": "d92d06f1e6ce90c4fac3226b243699a96bd509ad",
      "parents": [
        "54374f4f80b704cd93d11658f1ecc1aa7739df10"
      ],
      "title": "Coordinate DFL terrace services with existing gutters and concealed plant"
    },
    {
      "id": "3f0a15a543266fa50027e1392be813cade6a96bf",
      "parents": [
        "d92d06f1e6ce90c4fac3226b243699a96bd509ad"
      ],
      "title": "Keep DFL entry electrical interfaces on the dry hall wall"
    },
    {
      "id": "ad3bec2ea31e68ab27575ae2482c008c584b2268",
      "parents": [
        "3f0a15a543266fa50027e1392be813cade6a96bf"
      ],
      "title": "Include downstream pump feeder in DFL cable length allowance"
    },
    {
      "id": "f91861d29b73cf6e6384b26117c52aaa460bf23e",
      "parents": [
        "ad3bec2ea31e68ab27575ae2482c008c584b2268"
      ],
      "title": "Place DFL pool plant under owner deck with flush access hatch"
    },
    {
      "id": "67cb57a888ab9664b7eccac09be12ce4c2b918f2",
      "parents": [
        "f91861d29b73cf6e6384b26117c52aaa460bf23e"
      ],
      "title": "Integrate DFL service plant and add two-zone bedroom radiant heating"
    },
    {
      "id": "55d5169f57e606cf36d88effae507b1561dfc0ab",
      "parents": [
        "67cb57a888ab9664b7eccac09be12ce4c2b918f2"
      ],
      "title": "Coordinate DFL roof plant, solar array and shallow supported services"
    },
    {
      "id": "597eabfa27a3fb45dc964a4b1c0f4e8faaaf3c77",
      "parents": [
        "55d5169f57e606cf36d88effae507b1561dfc0ab"
      ],
      "title": "Anchor DFL corner pipe brackets and inverter to wall faces"
    },
    {
      "id": "ddf77435da2b4afdddc9cfed7d3d4b85f91a432c",
      "parents": [
        "597eabfa27a3fb45dc964a4b1c0f4e8faaaf3c77"
      ],
      "title": "Conceal barbecue greywater ventilation inside service cabinet"
    },
    {
      "id": "cede7a50bdcc1fed221e742bda70e072b052185b",
      "parents": [
        "ddf77435da2b4afdddc9cfed7d3d4b85f91a432c"
      ],
      "title": "Route storm bypass along pool edge instead of boundary wall"
    },
    {
      "id": "b069d02fb41e6de71343246761210a05fec6952e",
      "parents": [
        "cede7a50bdcc1fed221e742bda70e072b052185b"
      ],
      "title": "Prepare r07 services publication as descendant of r06"
    }
  ]
}